emka TECHNOLOGIES' hardware and software products for preclinical research
    what we do

  our products
  software software
  hardware hardware
    isolated organ systems
    pulmonary systems
    amplifiers
    usb acquisition
    noninvasive telemetry
    implantable telemetry
    rodent telemetry
    flowmeters
    pv systems
    transducers
     isometric trans.
     pressure trans.
     mikro-tip pres. cath.
     pv catheters
     electrophys. cath.
    food intake monitoring
    rodent ecg restrainer
    nibp from small rodents
  21 cfr part 11 21 cfr part 11
  arrange a demo arrange a demo
  request a quote request a quote
  latest projects latest projects
 
differential pressure transducer dpt for flow signal

The differential pressure transducer dpt is used in plethysmograph setups for studying pulmonary function.

The dpt transducer measures the pressure difference between the chamber containing the subject and either a reference chamber or the atmosphere.

The pressure difference varies with the subject's breathing, and is determined b… learn more


ask for a quote
» ask for a quote
differential pressure transducer dpt for flow signal
differential pressure transducer ppt for pulmonary pressure signal

The differential pressure transducer ppt is used in plethysmograph setups for studying pulmonary function. This transducer can measures the pressure of air or liquids.

In a learn more


ask for a quote
» ask for a quote
differential pressure transducer ppt for pulmonary pressure signal
liquid pressure transducer

For in vitro and in vivo applications in which easy and accurate liquid pressure monitoring is required (e.g. perfusion pressure, blood pressure...).

technical data:

  • measuring range: -50 to +300 mmHg.
  • working temperature: -15°C to +40°C.
  • combined error: less than ± 2% or 1mmHg.
  • dynamic response: 32 Hz min… learn more


ask for a quote
» ask for a quote
liquid pressure transducer


 
 
 
Rreceive alerts about emka TECHNOLOGIES' facebook page (new products, events, photos…) FACEBOOK Bookmark emka TECHNOLOGIES website for yourself and friends with DEL.ICO.US social bookmarking. DEL.ICO.US Use Digg to promote and share the best content on the web, like from www.emka.fr DIGG subscribe to emka TECHNOLOGIES' rss feed!