emka TECHNOLOGIES S.A.
59, bd. Général Martial Valin
75015 Paris - France
tel: + 33 (0)1 40 60 76 00
fax: +33 (0)1 40 60 65 55
e-mail: emka@emka.fr
emka TECHNOLOGIES Inc.
307 Annandale Road, suite 203
Falls Church, VA 22042 - USA
tel: +1 (703) 237-9001
fax: +1 (703) 237-9006
e-mail: emkatech@emkatech.com
      site map  
      newsletter
      contact us  
      legal info
  HomeCompanyProductsApplicationsServices
 
emka TECHNOLOGIES' hardware and software products for preclinical research
    what we do

  our products
  software software
    iox2
     key concepts
     advanced features
     external devices
     Datalink-DSI-ART
     analyzers
     cardiovascular
     pulmonary
     glp
     21 cfr part 11
     iox - interface boxes
     pv loops
    datanalyst
    ecgAUTO
    studyDESIGNER
    studyMANAGEMENT
    usersMANAGEMENT
    auditSERVER
  hardware hardware
  21 cfr part 11 21 cfr part 11
  arrange a demo arrange a demo
  request a quote request a quote
  latest projects latest projects
> home > products > software >iox2 > pv loops analyzer

pv loops analyzer
 

pressure-volume (pv) analyzer

The pv analyzer displays pv loops in real time. The analyzer requires two up to seven inputs (depending on the number of segments on the conductance catheter): pressure signal; total volume signal; and up tofive segment volume signals.

output
Two types of outputs are generated:

1- loop parameters

These are calculated in real time for every single loop. They are as follows:

  • maximum and minimum pressure
  • begin- and end-diastolic pressure
  • end-systolic pressure
  • developed pressure
  • systolic ejection period
  • diastolic filling period
  • mean systolic pressure, mean diastolic pressure
  • contraction time, Relaxation time
  • min/max dPdt
  • contractility index
  • time constant of relaxation (tau) (five Tau parameters are calculated, using five different methods)
  • average rate of pressure fall
  • dPdt at P, where P is a user-defined pressure (two parameters calculated, for the rising and falling part of the curve)
  • minimum and maximum volume
  • end-diastolic and end-systolic volumes
  • stroke volume
  • cardiac output
  • ejection fraction
  • stroke work
  • effective arterial elastance
  • maximum ventriculer power
  • preload-adjusted maximal power
  • potential energy
  • efficiency

2 - series data

Series data are calculated after the acquisition, for series of loopsthat the user selects. The user defines the type of series and then theanalyzer calculates the appropriate data, e.g. (i) time-varyingelastance graphs for occlusion series or (ii) correction volume forsaline dilution series.

end-diastolic pressure-volume relationship (EDPVR) and end-systolicpressure-volume relationship (ESPVR), which are both load-independentindices of LV performance

pv loop espvr

  • time-varying elastance
  • end-systolic elastance (Ees) also called maximal elastance (Emax)
  • preload recruitable stroke work (PRSW)
  • preload adjusted dP/dtmax
  • dP/dtmax vs end-diastolic volume (EDV)

features

  • α is entered manually or computed from a reference CO value.
  • exclude from analysis individual beats from the series
  • print graphs directly to the printer or create JPG images to clipboard
  • create a text file, including options for compatibility with PVAN (Millar Instruments’ software for processing pv loops).

 

 

setups


emka TECHNOLOGIES provides full setups for left ventricular PV loop studies for all species.

Several models of catheters are made by Millar Inc, including the Ultra-Miniature Pressure-Volume Catheters for rodents.

The pressure and volume signals travel from the catheter, to the signalconditioning unit (model MPVS-300 from Millar) then to a strain-gauge amplifier board in the amplifier mainframe.

The outputs from the amplifier mainframe go to the acquisition card of the PC via the interface box.

The PC must be running iox2 for the acquisition. The pressure-volume analyzer is an add-on modulespecifically designed for processing left ventricular PV loop data.

ask for a quote
» ask for a quote






iox - PV Loops
 
iox - pv loops
 
iox - pv loops
 
iox - pv loops
 
 
 
Rreceive alerts about emka TECHNOLOGIES' facebook page (new products, events, photos…) FACEBOOK Bookmark emka TECHNOLOGIES website for yourself and friends with DEL.ICO.US social bookmarking. DEL.ICO.US Use Digg to promote and share the best content on the web, like from www.emka.fr DIGG subscribe to emka TECHNOLOGIES' rss feed!
© 2004-2010 emka TECHNOLOGIES S.A. - site version 4.1