emka TECHNOLOGIES S.A.
59, bd. Général Martial Valin
75015 Paris - France
tel: + 33 (0)1 40 60 76 00
fax: +33 (0)1 40 60 65 55
e-mail: emka@emka.fr
emka TECHNOLOGIES Inc.
307 Annandale Road, suite 203
Falls Church, VA 22042 - USA
tel: +1 (703) 237-9001
fax: +1 (703) 237-9006
e-mail: emkatech@emkatech.com
      site map  
      newsletter
      contact us  
      legal info
  HomeCompanyProductsApplicationsServices
 
emka TECHNOLOGIES' hardware and software products for preclinical research
    what we do

  our products
  software software
  hardware hardware
    isolated organ systems
     tissue baths
     ios4 automate
     isolated heart
     vessel myographs
     stimulation
     thermal regulation
     perfusion
    pulmonary systems
    amplifiers
    usb acquisition
    noninvasive telemetry
    implantable telemetry
    rodent telemetry
    flowmeters
    pv systems
    transducers
    food intake monitoring
    rodent ecg restrainer
    nibp from small rodents
  21 cfr part 11 21 cfr part 11
  arrange a demo arrange a demo
  request a quote request a quote
  latest projects latest projects
 
STCx808
 
STCx808 series of stimulators

The STCx808 series of stimulators (x is 1, 2, 4 or 8 channels) are constant current stimulators with maximum power of 800 mA/80 V (64 W) on each channel and independent output insulation.

The following settings and characteristics can be adjusted independently for each channel:

  • Power output (at any time).
  • Switch to set output power as a multiple of threshold power (minimum power necessary to obtain organ reaction).
  • Stimulation mode: positive monopolar, negative monopolar, bipolar.

Other settings and characteristics common to all channels are:

  • Duration of pulse (0 to 10 ms)
  • Connectors to simultaneously connect the stimulator to amplifier output and oscilloscope input, in order to display the stimulation pulse and organ response on the oscilloscope. The delay setting for the oscilloscope can be adjusted. Channel selection through analog multiplexer.
  • Stimulation impulse triggered by:
    • A STC4050 stimulator (also able to generate double impulses), or
    • iox software run on a PC, or
    • by any other stimulator.
 
ask for a quote
» ask for a quote
related software : iox2
related hardware : isolated organ systems - stc4050



STCx808
 
 
 
Rreceive alerts about emka TECHNOLOGIES' facebook page (new products, events, photos…) FACEBOOK Bookmark emka TECHNOLOGIES website for yourself and friends with DEL.ICO.US social bookmarking. DEL.ICO.US Use Digg to promote and share the best content on the web, like from www.emka.fr DIGG subscribe to emka TECHNOLOGIES' rss feed!